원래 장소: | 중국 |
브랜드 이름: | kacise |
인증: | CE,FDA |
모델 번호: | KBU601 |
최소 주문 수량: | 0-100 |
---|---|
포장 세부 사항: | 일반적인 포장 또는 관례 포장 |
배달 시간: | 10-15 일 |
지불 조건: | L/C (신용장), 인수 인도, D/P (지급도 조건), 전신환, 웨스턴 유니온, 머니그램 |
공급 능력: | 100 |
호스트 :공급 전압: | AC220V 또는 DC24V (2개 중 하나를 선택하세요) | 호스트 :소비 전력: | <2w> |
---|---|---|---|
호스트 :디스플레이: | LCD 중국 디스플레이 / TFT 컬러 LCD (맞춤형 버전) | 호스트 :측정 범위: | 0~100NTU、0~500NTU、0~5000NTU 0~10000NTU、0~25g/L、0~50g/L |
호스트 :결의안: | 0.01NTU、0.1NTU、1NTU、0.01mg/L | 호스트 :정확성: | 2-3% 교정 정확도 |
하이 라이트: | 304 스테인레스 강 용존 산소 Probe,AC220V 용존 산소 Probe,2W 용존 산소 미터 |
KFDO600 gray host dissolved oxygen meter water quality for aquaculture 304 stainless steel probe
Product Introduction
Fluorescence dissolved oxygen meter KFDO500 is based on the quenching principle of active fluorescence by specific substances in physics.
The modulated green light hits the fluorescent material for a period of time to excite and emit red light. Because oxygen molecules can take away energy (quenching effect),
Therefore, the time and intensity of red light is inversely proportional to the concentration of oxygen molecules.
We used a red light source synchronized with the green light as a reference,
Measure the direct phase difference between the excited red light and the reference light, and compare it with the internal calibration value,
So as to calculate the concentration of oxygen molecules, and output the final value after temperature compensation.
Performance characteristics:
1. Principle of fluorescence quenching, no electrolyte digestion, maintenance-free
2. No oxygen consumption, no flow rate and agitation requirements
3. No interference from chemicals such as sulfides
4. High resolution and measurement accuracy
5. Chinese menu operation is simple, easy to operate and master
6. Special thickened cap film, not easy to wear, longer service life
7. The unique protective cover design prevents irreversible damage caused by the cap film hitting hard objects during the sensor reuse process
Feathre Chart
Electrode installation
Electrodes are very delicate components and must be installed correctly. The wrong installation can result in damage to the electrodes or irreversible damage.The electrode is installed in pipeline.Immersion. Both French and French installations are available.
Do not put the electrode directly into the water. Instead, select the electrode mounting bracket or the flow cup for fixation.Before installation, please make sure to use the raw material belt (3/4 thread) to do waterproof sealing work, to avoid water entering into the electrode and causing short circuit of the electrode cable.
During water outage, make sure that the electrode is immersed in the tested liquid or wear the protective cap with the protective liquid inside. If the temperature is low and the water is stopped for a long time in winter, add antifreeze device or take back the room to add water and store.Otherwise, the service life will be shortened.
Technical Parameters of Fluorescence Dissolved Oxygen Analyzer
Class | Performance | Parameter |
Host | Supply Voltage | AC220V or DC24V (choose one of the two) |
Power Consumption | <2W | |
Display | LCD Chinese display/TFT color LCD (customized version) | |
Measuring range |
0~100NTU,0~500NTU,0~5000NTU 0~10000NTU,0~25g/L,0~50g/L |
|
Resolution | 0.01NTU,0.1NTU,1NTU,0.01mg/L | |
Precision | 2-3% calibration accuracy | |
Operating Temperature | Transmitter -10~65℃ | |
Material | PVC | |
Protection Level | I65/IP67(customized version) | |
Signal Output |
485 communication/4-20mA analog output/support HART protocol/NB.GPRS.LORA Communication (function option) |
|
Installation Method | Wall mount | |
Sensor | Supply Voltage | DC5V |
Protection Level | ip68 | |
Temperature | 0-60℃ | |
Sensor Material | 304 stainless steel (input type), PVC (circulation type) | |
Cable Length | Standard 10 meters (extendable) | |
Operating Temperature | 0-60℃ | |
Storage Temperature | -10-60℃ | |
Installation Method | Bracket drop-in installation / flow-through wall-mounted installation. |
Ordering Information selection table
Ordering Information selection table | ||||
KFDO600 | Fluorescence Dissolved Oxygen Meter | |||
Power supply | ||||
DC24V | ||||
AC220V | ||||
Cable length | ||||
10m | ||||
15m | ||||
20m | ||||
30m | ||||
Signal output | ||||
Only 4-20mA | ||||
Only 485 | ||||
Also with 4-20mA , 485 signal output
|
||||
Special custom signal | ||||
KFDO600- | AC220V | 10m | Only 485 |
with AC220V adapter, cable between host and sensor,The cable length is 10 meters, the sensor is equipped without temperature compensation, and is equipped with only 485 communication signal output.
|
Contact us
Website: www.kacise.com
Phone: +86-17719566736
Email: sales@kacise.com
Location: Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China
담당자: Ms. Evelyn Wang
전화 번호: +86 17719566736
팩스: 86--17719566736
주소: I 도시, No11의 TangYan 남쪽 도로, 옌타 구, 시안, 산시 성, 중국.
공장 주소:I 도시, No11의 TangYan 남쪽 도로, 옌타 구, 시안, 산시 성, 중국.