logo
> 상품 > 정밀 압력 센서 >
Honeywell 2CCP Series Dual Head Cable-Pull Safety Switch with IP54 and NEMA 1 Ratings for Emergency Stop Applications

Honeywell 2CCP Series Dual Head Cable-Pull Safety Switch with IP54 and NEMA 1 Ratings for Emergency Stop Applications

IP54 Cable-Pull Safety Switch

NEMA 1 Emergency Stop Switch

Dual Head MICRO SWITCH

브랜드 이름:

Honeywell

모델 번호:

2CCP 시리즈

저희와 연락
인용 을 요청 하십시오
제품 세부 정보
충격:
15 G
정격열전류(Ith):
10 A
정격 충격량(Uimp):
2500 V
정격절연전압(Ui):
300 v
사용 가능한 금도금 전류(해당되는 경우):
1mA ~ 50mA, 최대 60Vdc/최대 125Vac
강조하다:

IP54 Cable-Pull Safety Switch

,

NEMA 1 Emergency Stop Switch

,

Dual Head MICRO SWITCH

지불 및 배송 조건
최소 주문 수량
1PCS
포장 세부 사항
각 장치에는 개별 상자가 있으며 모든 상자에는 표준 패키지에 포장되거나 고객 요청이 가능합니다.
배달 시간
5-8 근무일
지불 조건
MoneyGram, Western Union, T/T, D/P, D/A, L/C.
공급 능력
주당 1000 조각/조각 협상 가능
제품 설명
Honeywell 2CCP Series Dual head cable pull. UL, cUL, CE, SIL3 capable. lP54. NEMA 1. Silver contacts.
The 2CCP, Honeywell's newest MICRO SWITCH Cable-Pull Safety Switch, provides an economical switching solution for an easily accessible emergency stop function along conveyors and machines. The 2CCP provides reliable performance, a highly configurable platform, easy installation, simplified maintenance, and faster equipment restart to meet the needs of a wide range of end-users.
APPLICATIONS
Long conveyor systems found in:
Warehouses and distribution centers
Post and parcel facilities
Food & beverage or pharmaceutical production
Large machinery found in:
Packaging equipment
Assembly lines like automotive
Woodworking and textiles
2CCP FEATURES & BENEFITS
FEATURES BENEFITS
Dual direction Covers cable spans up to 656 ft*. Fewer number of switches required per installation creates savings on unit and wiring costs
Configurable platform Many options available within one package size. 576 possible SKU combinations. Options for conduit ports, contacts, actuation direction, LED, E-stop, and restart button
Direct-opening, snap-action contacts Contacts are held closed when the actuating cable is under proper tension and the reset knob is set to the run position. Upon activation, a cam positively open the NC contacts. The snap-action operation causes the mechanical latch almost immediately
Latches on both slackened and pulled cable Provides tension loss monitoring due to wire breakage or thermal expansion
Wide tolerance zone for cable tensioning Protects against nuisance tripping and the effects of thermal expansion. ±30°F for cable runs up to 500 ft. Longer runs achievable at smaller temperature windows
Integral reset mechanism NC switch contacts remain open until the unit is reset by properly tensioning the cable and manually rotating the blue reset knob to "Run" condition following switch actuation
Restart button Equipment is not allowed to restart automatically after the cable-pull switch is reset. The integrated restart button can be used to send a signal back to the PLC for equipment start. This is in lieu of installing a local control station or using an existing HMI
Improved LED More light intensity and better side viewing ensures switch status can be seen easily from a distance. Available in 24 Vdc, 120 Vac, or 240 Vac
E-stop button Provides E-stop access even at the extreme ends of the span
Replaceable front cover Units with an E-stop are prone to damage. Impact-resistant plastic cover has been designed for fast and economic replacement. LED and restart button are mounted to base of unit and do not require replacement or rewiring
Improved tension window Magnified window and clear markings makes system setup and rope tension maintenance faster and more precise
External mounting holes Front cover does not need to be removed to access mounting holes creating easier installation and maintenance access
Large wiring cavity with straight through wiring Easier access to contact block allows for faster and simpler wiring
Optional rear conduit port Option to route wiring through the back of the unit for easier installation and to eliminate looping cable
TABLE 1. SPECIFICATIONS
DESIGNATION AND UTILIZATION CATEGORY RATED OPERATIONAL CURRENT IE (A) AT RATED OPERATIONAL VOLTAGE (V)
24 V 120 V 240 V
AC15 (Contact Rating) A300 - 6 A
DC13 (Contact Rating) Q300 2.8 A 0.55 A
Rated thermal current (Ith): 10 A
Rated impulse withstand (Uimp): 2500 V
Rated insulation voltage (Ui): 300 V
Usable gold-plated current (if applicable): 1 mA to 50 mA, 60 Vdc max./125 Vac max.
Shock: 15 g
Conditional short-circuit current: 1000 A
Sealing: IP54; NEMA 1
Pollution code: 3
Operating temperature range: -40 °C to 85 °C [-40 °F to 185 °F]
Short-circuit protective device (type/maximum rating): Class J fuse (10 A/600 V)
Vibration: 10 Hz to 500 Hz, 5 g
Mechanical life: 375,000 operations
Complies with: • Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU • Machinery Directive 2006/42/EC only as the directives relate to the components being used in a safety function • IEC/EN 60947-1, IEC/EN 60947-5-1, IEC/EN 60947-5-5 • EN ISO 13850 compliance • UL Category NISD, Emergency Stop Devices

MCTF (Mechanical Life): >375,000 cycles with single-sided confidence limit of 100 % MCTF (Electrical Life): >50,000 cycles with single-sided confidence limit of 87.5 % Highest SIL Capability: SIL3 (HFT:1), IEC 61508-2 Proof Test Interval: 1 Year
Honeywell 2CCP Series Dual Head Cable-Pull Safety Switch with IP54 and NEMA 1 Ratings for Emergency Stop Applications 0 Honeywell 2CCP Series Dual Head Cable-Pull Safety Switch with IP54 and NEMA 1 Ratings for Emergency Stop Applications 1 Honeywell 2CCP Series Dual Head Cable-Pull Safety Switch with IP54 and NEMA 1 Ratings for Emergency Stop Applications 2