logo
> 상품 > 수질 감지 센서 >
Surface Scattering Light Turbidity Detector with 0-2000 NTU Range and LED Light Source for Water Quality Analysis

Surface Scattering Light Turbidity Detector with 0-2000 NTU Range and LED Light Source for Water Quality Analysis

0-2000 NTU range Turbidity Detector

Surface scattering method Turbidity Analyzer

LED light source Water Quality Sensor

브랜드 이름:

Yokogawa

모델 번호:

TB830D

저희와 연락
인용 을 요청 하십시오
제품 세부 정보
측정 방법:
표면 산란 방법
측정 범위 (탁도 표준 : 포르 마진):
0-2 ~ 0-2000 NTU
온도:
0 ~ 50 ° C
유량:
1.5 ~ 2 L/분
압력:
500 kPa Max
강조하다:

0-2000 NTU range Turbidity Detector

,

Surface scattering method Turbidity Analyzer

,

LED light source Water Quality Sensor

지불 및 배송 조건
최소 주문 수량
1pcs
포장 세부 사항
각 장치에는 개별 상자가 있으며 모든 상자에는 표준 패키지에 포장되거나 고객 요청이 가능합니다.
배달 시간
5-8 일
지불 조건
L/C, D/A, D/P, T/T, Western Union, MoneyGram
공급 능력
주당 1000 조각/조각 협상 가능
제품 설명
Surface Scattering Light Turbidity Detector TB830D
Reduce maintenance - Digital solution for water quality
Many of our customers face these challenges - Yokogawa Turbidity Analyzers TB800 series resolve them.
Yokogawa's turbidity meters have been developed and improved to suit various applications in water treatment plant turbidity measurement. As a result, we have accumulated many achievements and gained the trust of our customers since our first product was launched in 1959.
Japan's most trusted turbidimeter*.
The TB830D is part of the SENCOM4.0 platform family and can connect to FLXA402T. Thanks to a smart unit equipped detector, TB830D gives you more insight into the ordinary operation.
The TB830D is a turbidity analyzer that equipped LEDs as the light source, is dirt-resistant, and offers reliable measurements and reduced OPEX due to the addition of advanced diagnostic functions.
*Based on a Yokogawa survey in 2019
Less susceptible to contamination due to non-contact with the sample
Compatible with various applications
  • Surface scattering measurement method minimizes contamination
  • LED light source for 3-year long life and reduced maintenance costs
  • High sensitivity and high accuracy with long-standing reliability
  • Good linearity and reproducibility
  • Measuring range from 0-2 NTU to 0-2000 NTU
  • Improved cleaning system reduces maintenance
  • Easy-to-clean cell structure (by GS)
Surface Scattering Light Turbidity Detector with 0-2000 NTU Range and LED Light Source for Water Quality Analysis 0
Multi sensor input
Not only Turbidity Detector but also Chlorine Sensor Unit, pH sensor and conductivity sensor are connectable to one transmitter.
Surface Scattering Light Turbidity Detector with 0-2000 NTU Range and LED Light Source for Water Quality Analysis 1
Application
Turbidity of tap water, sewage, river water and water used in general processes.
Water Purification Treatment
  • Sedimentation
  • Flocculation
  • Settling Basins
  • Clean water reservoir
  • Distributing pump
  • Distribution tank & Piping
Wastewater Treatment
  • Discharge/Reuse
Surface Scattering Light Turbidity Detector with 0-2000 NTU Range and LED Light Source for Water Quality Analysis 2
Specifications
Measuring method Surface scattering method
Measuring Range
(Turbidity standard: Formazin)
0-2 to 0-2000 NTU
Sample Conditions Temperature: 0 to 50°C
Flow Rate: 1.5 to 2 L/min
Pressure: 500 kPa max
Power Supply 100 to 240 V DC, 50/60 Hz
Digital Communication Modbus TCP/IP, Modbus RTU
Installation Indoor (Outdoor use requires protection against rain. Direct sunlight must be avoided.)
Cleaning system Automatic wash
Performance
Linearity 0-1000 NTU: ±2% of reading or ±0.04 NTU whichever is greater
over 1000 NTU: ±4% of reading
Repeatability ±1% of reading or ±0.02 NTU whichever is greater

문의사항을 직접 저희에게 보내세요

개인정보 보호 정책 중국 좋은 품질 수질 감지 센서 공급자. 저작권 2018-2025 Xi'an Kacise Optronics Co.,Ltd. 모든 권리는 보호됩니다.