문자 보내
제품 소개수질 감지기

Extendable KPH500 14PH 2000mv Water Quality Sensor

Extendable KPH500 14PH 2000mv Water Quality Sensor

  • Extendable KPH500 14PH 2000mv Water Quality Sensor
  • Extendable KPH500 14PH 2000mv Water Quality Sensor
  • Extendable KPH500 14PH 2000mv Water Quality Sensor
Extendable KPH500 14PH 2000mv Water Quality Sensor
제품 상세 정보:
원래 장소: 중국
브랜드 이름: kacise
인증: CE,FDA
모델 번호: KBU601
결제 및 배송 조건:
최소 주문 수량: 0-100
가격: $100-$2000
포장 세부 사항: 일반적인 포장 또는 관례 포장
배달 시간: 10-15 일
지불 조건: L/C (신용장), 인수 인도, D/P (지급도 조건), 전신환, 웨스턴 유니온, 머니그램
공급 능력: 100
접촉
상세 제품 설명
센서 :보호 수준: IP68 센서 :온도: 0-60' C
센서 :재료: PVC 센서 :케이블 길이: 데다이카테드 PH 케이블, 표준 5 미터 (신장가능한)
센서 :작동 온도: 0-60' C 센서 :저장 온도: -10-60' C
하이 라이트:

2000 밀리볼트 수질 Sensor

,

14PH 수질 Sensor

,

ip68 신장가능 수질 센서

KPH500 PH/ORP sensor,Compact, flexible and easy to use,black PVC,gray meter host,water quality test.

Production Introduction
The PH/ORP meter is a precision meter used to detect the pH/oxidation-reduction potential of liquids. It is designed with a microcomputer based on the principle of the primary battery and is simple to operate and easy to maintain. Not affected by color, turbidity, colloidal substances, oxidants and reducing agents, it is suitable for the determination of various media such as clean water, wastewater, industrial water, chemical reagents, etc., and is widely used in agriculture, environmental protection and industry.
 
 
 
The sensor uses a composite electrode, which can eliminate the influence of the inconstant "K" value,
A long-term, stable and accurate measurement of PH is realized. The internal structure of the sensor is shown on the right.
 
 
Extendable KPH500 14PH 2000mv Water Quality Sensor 0
Extendable KPH500 14PH 2000mv Water Quality Sensor 1 
 
 

 

 Extendable KPH500 14PH 2000mv Water Quality Sensor 2
 
 

 

PH/ORP size structure chart
 
Host size
 
 
 
Extendable KPH500 14PH 2000mv Water Quality Sensor 3
 
 
Sensor size
 
Extendable KPH500 14PH 2000mv Water Quality Sensor 4
Extendable KPH500 14PH 2000mv Water Quality Sensor 5 

 

 


 

PH/ORP technical parameters
 
 
 

Class Performance PH parameter OPR parameter
Host Measuring range 0-14PH -2000mv-2000mv
Resolution 0.01PH 1mv
Precision 2% Calibration accuracy
Operating Temperature Transmitter 0-65℃
Material PVC
Protection Level I65/IP67(customized version)
Signal Output

485 communication/4-20mA analog output/support HART protocol/NB.GPRS.LORA

Communication (function option)

Supply Voltage AC220V or DC24V (choose one of the two)
Power Consumption <1W
Display LCD Chinese display/TFT color LCD (customized version)
Installation Method Wall mount
Sensor Temperature Compensation Automatic temperature compensation
Protection Level ip68
Temperature 0-60℃
Sensor Material PVC
Cable Length Dedicated PH cable, standard 5 meters (extendable)
Operating Temperature 0-60℃
Storage Temperature -10-60℃
Installation Method Bracket drop-in installation

 
 
 
 

Ordering Information Selection Table
KPH500 PH/ORP analyzer
Power supply DC24V
AC220V
Cable length 5m
10m
15m
20m
Temperature compensation Sensor without temperature compensation
Sensor with temperature compensation
Signal output Only 4-20mA
Only 485
Also with 4-20mA , 485 signal output
Special custom signal
KPH500-P-DC24V-5m-Sensor without temperature compensation-Only 485 PH host, with DC24V adapter, cable between host and sensor,The cable length is 5 meters, the sensor is equipped without temperature compensation, and is only 485 communication.
KPH500-R-AC220V-10m-Sensor with temperature compensation-Only 485

Optional ORP host, with 220V adapter, line between host and sensor
The cable length is 10 meters, the sensor with temperature compensation, and is equipped with only 485 communication signal output.

 

Q&A

1.Can alkaline kill bacteria?

Raising pH (to an alkaline state) increases the immune system's ability to kill bacteria, concludes a study conducted at The Royal Free Hospital and School of Medicine in London. The viruses and bacteria which cause bronchitis and colds thrive in an acidic environment.

 

 

2.What pH kills E coli?

Previous studies have demonstrated the ability of E. coli O157:H7 to survive pH 3.0 for 2 to 5 h (2, 5, 8, 15). In this study, we have demonstrated the ability of a nontoxigenic strain of E. coli O157:H7 to survive prolonged exposure to pH 3.0.

 

3.How can I make my body more alkaline?

Most fruits and vegetables, soybeans and tofu, and some nuts, seeds, and legumes are alkaline-promoting foods, so they're fair game. Dairy, eggs, meat, most grains, and processed foods, like canned and packaged snacks and convenience foods, fall on the acid side and are not allowed.

 

4.What happens if the pH of your blood changes?

An increase in alkaline causes pH levels to rise. When the levels of acid in your blood are too high, it's called acidosis. When your blood is too alkaline, it is called alkalosis. Respiratory acidosis and alkalosis are due to a problem with the lungs.

 

Avoiding harsh soaps and douching. Soaps typically have a high pH, and using them to clean the vaginal area may increase vaginal pH. ...

Taking a probiotic supplement or suppository. ...

Changing tampons regularly. ...

Using barrier protection during sex.

 

5.What pH is safe to touch?

The optimal pH of human skin is 5.5 and you can measure it with a piece of litmus paper. Your sweat with the sebum on your skin to form something called an acid mantle, which has a pH of 4 to 5.5.

 

 

 

 

Contact us
Website: www.kacise.com
Phone: +86-17719566736
Email: sales@kacise.com
Location: Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China
 
 

연락처 세부 사항
Xi'an Kacise Optronics Co.,Ltd.

담당자: Ms. Evelyn Wang

전화 번호: +86 17719566736

팩스: 86--17719566736

회사에 직접 문의 보내기 (0 / 3000)

접촉

주소: I 도시, No11의 TangYan 남쪽 도로, 옌타 구, 시안, 산시 성, 중국.

공장 주소:I 도시, No11의 TangYan 남쪽 도로, 옌타 구, 시안, 산시 성, 중국.